Dr. Fooke laboratories develop, manufacture and distribute immunological in-vitro Diagnostics.
IN-VITRO ALLERGY DIAGNOSTICS
Test Procedure Specific Ige Tests with Allergen Discs
For specific IgE Tests with Allergen Discs you need:
- Allergen Discs
- Standard Curve = quantitative Reference System with 4 or 6 Standards
- Reagents = Enzyme Kit
- Controls
Tube System Enzymatic:
- Allergen Discs:
- Quantitative Reference System: 074000PQ (for 6 Curves in Double Determination)
- Enzyme Kit: 05010K for 100 Determinations or 05030K for 300 Determinations
- Controls: 07001(Positive Control) and
- 07002 (Negative Control)
Test Procedure Semi Automatic (ALLERG-O-SYSTEM)
With 4 Standards
- Allergen Discs:
- Quantitative Reference System: 074000PQ (for 6 Curves in Double Determination)
- Enzyme Kit: 0540200PKL for 200 Determinations or 0541000PKL for 1000 Determinations
- Controls: 07001 (Positive Control) and 07002 (Negative Control)
With 6 Standards
- Allergen Discs:
- Quantitative Reference System: 076000PQ (for 6 Curves in Double Determination)
- Enzyme Kit: 0560200PKL for 200 Determinations or 0561000PKL for 1000 Determinations
- Controls: 07001 (Positive Control) and 07002 (Negative Control)
Test Procedure Fully Automated (ALLERG-O-MAT)
With 4 Standards
- Allergen Discs:
- Quantitative Reference System: 074010PQ (for 6 Curves in Double Determination)
- Enzyme Kit: 0541001PKL for 1000 Determinations
- Controls: 07011 (Positive Control) and 07012 (Negative Control)
With 6 Standards
- Allergen Discs:
- Quantitative Reference System: 076010PQ (for 6 Curves in Double Determination)
- Enzyme Kit: 0561001PKL for 1000 Determinations
- Controls: 07011(Positive Control) and 07012 (Negative Control)
Test Procedure Specific Ige Tests with Biotinylated Liquid Allergens
- Biotinylated Liquid Allergens
- Standard Curve = quantitative Reference System with 6 Standards
- Reagents = Enzyme Kit
- Control
- Biotinylated Allergens: Code-FL
- Quantitative Reference System: 07050FL (for 6 Curves in Double Determination)
- Enzyme Kit: 0520960FL for 96 Determinations
- Controls: 07005 (Positive Control) and 07006 (Negative Control)
Test Procedure Specific Ige by Rapid Test
For specific IgE by Rapid Test you need:
- ALFA Basis Set REF: 180001 (1 Det.)
- REF: 1800010 (20 Det.)
- Allergen Solution:
Test Performance Total Ige
For Total IgE Tests you need:
Test in Microplates
CP
- 08100CP Enzyme Kit AP with Calibrators and Controls
- 08102CP Enzyme Kit HRP with Calibrators and Controls
Test in Microplates with Biotinylated Reagents
CP 08100FL Enzyme Kit with Calibrators and Controls
Test Procedure Specific Igg
For specific IgG Tests you need:
- Allergen coated Micro strips
- Standard Curve and Controls = quantitative Reference System
- Reagents = Enzyme Kit
- Controls (included in Reference System)
Test Procedure Semi Automatic (ALLERG-O-SYSTEM):
- Allergen coated Micro strips: 13 Code-G
- Quantitative Reference System: 12001PG (For 3 Curves in Double Determination)
- Enzyme Kit: 10100PG for 100 Determinations
Test Procedure Fully Automated (ALLERG-O-MAT):
- Allergen coated Micro strips: 13 Code-G
- Quantitative Reference System: 12002PG (for 4 Curves in Double Determination)
- Enzyme Kit: 10200PG for 200 Determinations
Test Procedure Specific Igg4
For specific IgG4 Tests you need:
- Allergen coated Micro strips
- Standard Curve = quantitative Reference System
- Reagents = Enzyme Kit
Test Performance Semi Automatic (ALLERG-O-SYSTEM):
- Allergen coated Micro strips 13 Code-G
- Quantitative Reference System: 12004PG (For 3 Curves in Double Determination)
- Enzyme Kit: 10104PG for 100 Determinations
AUTOIMMUNE DIAGNOSTICS
- 25001 PM1-Alpha ELISA;
ELISA for the semi-quantitative determination of anti-PM1-Alpha antibodies in human serum and plasma
- 25002 Ribosomal P ELISA;
ELISA for the semi-quantitative determination of anti-CENP antibodies in human serum and plasma
- 25004 CENP ELISA;
ELISA for the semi-quantitative determination of anti-CENP antibodies in human serum and plasma
- 25005 dsDNA ELISA;
ELISA for the semi-quantitative determination of anti-dsDNA antibodies in human serum and plasma
BIOANALYTICS
License for Working with Pathogenic Germs
- License for working with pathogenic germs according to Infektionsschutzgesetz
- Analysis of official samples according to § 42 LMBG Accreditation by AKS-P-20511-EU at Staatliche Akkreditierungsstelle Hannover
- Certificate according to DIN EN ISO 9001: 2000; DIN EN ISO 17025: 2001
Analysis of Foods (LMBG §35 Amtliche Sammlung)
- Microbial Limits Testing
- Indicator Organisms
- Pollution- and Pathogenic Agents
- Storage and Stability Tests
Analysis of Cosmetics and Drugs (DAB 10; Ph. Eur. or USP)
- Sterility Tests
- Microbial Limits Testing
- Identification of Microorganisms
- Antimicrobial Preservatives Efficiency Test
Bacteriological Analysis of Drink Water according to TrinkWVO 2001
- Microbial Limits Testing
- Biological Indicators
- Pathogenic Agents (incl. Legionella)
Biological Indicators and Environmental Monitoring
- Pad Probes wet or dry (DIN 10113-1)
- Copy Contact Probes (DIN 10113-3)
- Air Sanitation Analysis: (Microbial count / m³, Mould count / m³ etc.) with MD8 Air-sampler (Sartorius)
Analysis of Waste Water and Sludge
- Salmonella, Pathogenic Agents
- LUMIStox Luminobacter test (DR.LANGE) for the Determination of Toxicity according to DIN 38412 Part 34/341
Germ-Identification and Risk-Analysis for Biotechnology Systems
Coming Soon